CCH – Ceiling-mounted fan convector for cooling and heating

  • High heating/cooling capacity through forced convection
  • Suitable for heat pumps
  • Quiet operation
  • Short heating/cooling response time
  • Low electricity consumption
  • Heating capacity up to 4,343 W/m
  • Cooling capacity up to 2,196 W/m

Function

with a fan

heating

cooling

ventilation

dry environment

heat pump

Dimensions

260-380 mm

125-195 mm

900-3000 mm

Colour variants

white

RAL (surcharge)

4343  |  2196  W/m
Inquire
Contact form
Name (Optional)
Last name
E-mail
Phone Number
Message
By submitting you agree to the processing of personal data pursuant to Act No. 101/2000 Coll. on the Protection of Personal Data.
Submit form

Technical parameters

Input parameters for calculation

Heating
Cooling

Length (mm)

Atypical length (mm)

Inlet water temperature

Outlet water temperature

Interior temperature (°C)

Inlet water temperature

Outlet water temperature

Interior temperature (°C)

Output parameters

Q [W]
Performances
q [l/h]
Water flow
∆P [kPa]
Water pressure drop
V [l]
Heat exchanger water volume
Enter input parameters
The technical parameters are set according to the relevant standards. In fact, they may vary depending on the location of the convector, the cover grille, the connection type.
The technical parameters are set according to the relevant standards. In fact, they may vary depending on the location of the convector, the cover grille, the connection type.
The technical parameters are set according to the relevant standards. In fact, they may vary depending on the location of the convector, the cover grille, the connection type.
The technical parameters are set according to the relevant standards. In fact, they may vary depending on the location of the convector, the cover grille, the connection type.
The technical parameters are set according to the relevant standards. In fact, they may vary depending on the location of the convector, the cover grille, the connection type.
The technical parameters are set according to the relevant standards. In fact, they may vary depending on the location of the convector, the cover grille, the connection type.
The technical parameters are set according to the relevant standards. In fact, they may vary depending on the location of the convector, the cover grille, the connection type.
The technical parameters are set according to the relevant standards. In fact, they may vary depending on the location of the convector, the cover grille, the connection type.

FROM SOLUTION PROPOSALS TO IMPLEMENTATION ASSISTANCE

Can we help your project?

Take advantage of our years of experience and involve us to your project. We will advise you on the most suitable choice of heating and cooling system, we also conduct our own measurements and discuss with the contractor the ideal way of installation.

MCE 2026 Milan – Meet us there

Two years have passed, and we can’t wait to be part of the MCE trade fair in Milan once again. We will be delighted to meet you and share our new solutions and innovations. We look forward to seeing you!