KP – Windowsill convector

Special windowsill convector with a fan.

  • high forced convection output
  • rapid room heating
  • heating also when the fan is off
  • low electricity consumption
  • safe 12V DC voltage
  • suitable for use in windowsills according to the given dimensions
  • windowsill in beech or oak without surface treatment
  • standard lengths: 900 / 1000 / 1250 / 1500 mm

Function

with a fan

heating

dry environment

Dimensions

272 mm

135 mm

900 - 1500 mm

1322  W/m
Inquire
Contact form
First name
Last name
E-mail
Phone
Message
By submitting you agree to the processing of personal data pursuant to Act No. 101/2000 Coll. on the Protection of Personal Data.
Submit form

Technical parameters

Input parameters for calculation

Length (mm)

Atypical length (mm)

Inlet water temperature

Outlet water temperature

Interior temperature (°C)

Output parameters

Q [W]
Performances
q [l/h]
Water flow
∆P [kPa]
Water pressure drop
V [l]
Heat exchanger water volume
Enter input parameters
The technical parameters are set according to the relevant standards. In fact, they may vary depending on the location of the convector, the cover grille, the connection type.
The technical parameters are set according to the relevant standards. In fact, they may vary depending on the location of the convector, the cover grille, the connection type.
The technical parameters are set according to the relevant standards. In fact, they may vary depending on the location of the convector, the cover grille, the connection type.
The technical parameters are set according to the relevant standards. In fact, they may vary depending on the location of the convector, the cover grille, the connection type.
The technical parameters are set according to the relevant standards. In fact, they may vary depending on the location of the convector, the cover grille, the connection type.
The technical parameters are set according to the relevant standards. In fact, they may vary depending on the location of the convector, the cover grille, the connection type.
The technical parameters are set according to the relevant standards. In fact, they may vary depending on the location of the convector, the cover grille, the connection type.
The technical parameters are set according to the relevant standards. In fact, they may vary depending on the location of the convector, the cover grille, the connection type.

FROM SOLUTION PROPOSALS TO IMPLEMENTATION ASSISTANCE

Can we help your project?

Take advantage of our years of experience and involve us to your project. We will advise you on the most suitable choice of heating and cooling system, we also conduct our own measurements and discuss with the contractor the ideal way of installation.

CONVECTORS - Save up to 50% on heating

CONVECTORS -

THE MOST ECONOMICAL HEATING SOLUTION TO A HEAT PUMP 

More here »